{"id":560,"date":"2021-08-23T13:32:09","date_gmt":"2021-08-23T13:32:09","guid":{"rendered":"https:\/\/dipylonmedical.com\/?post_type=product&#038;p=560"},"modified":"2022-07-03T09:41:44","modified_gmt":"2022-07-03T09:41:44","slug":"cell-dyn-emerald-22","status":"publish","type":"product","link":"https:\/\/dipylonmedical.com\/nl\/product\/cell-dyn-emerald-22\/","title":{"rendered":"Abbott CELL DYN Emerald 22 Hematologie Analyzer"},"content":{"rendered":"<p style=\"text-align: justify;\"><strong>CELL DYN Emerald 22<\/strong> uses UNI-FLOW technology, including cyanide- and formaldehyde-free Lyse, flow cell, and optical bench. The Lyse destroys the red blood cell stroma and stabilizes the white blood cells, while it creates a chromagen for hemoglobin measurement using the same dilution.<\/p>\n<p style=\"text-align: justify;\">The CELL-DYN Emerald 22 AL is a full performance, automated optical 5-part differential hematology analyzer that conserves valuable laboratory space with a small footprint and only two reagents, plus an onboard cleaner. It optimizes hematology workflow with 50 tubes load-up capacity and reducing hands-on time with touch-free scheduled daily maintenance, start-up, and shutdown.<\/p>\n<p style=\"text-align: justify;\">\n<style>.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }<\/style>\n<\/p>\n<div class=\"embed-container\" style=\"text-align: justify;\"><iframe src=\"https:\/\/www.youtube.com\/embed\/_nRyQs13YcY\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/div>\n<p style=\"text-align: justify;\">\n<p style=\"text-align: justify;\">\n<h2 style=\"text-align: justify;\"><strong>Benefits of the CELL DYN Emerald 22 Hematology Analyzer<\/strong><\/h2>\n<ul style=\"text-align: justify;\">\n<li><strong>COMPACT DESIGN<\/strong> &#8211; The CELL DYN Emerald 22 is one of the smallest 5-part differential analyzers on the market and helps laboratories like yours conserve valuable workspace.<\/li>\n<li><strong>SMALL AND POWERFUL<\/strong>\u00a0&#8211; Specifically designed with space in mind doesn\u2019t mean less functionality \u2014 it means more. The CELL-DYN Emerald 22 includes a numeric keypad entry, reagent tray, and integrated color touchscreen monitor.<\/li>\n<li><strong>EASY AND AUTOMATED<\/strong> &#8211; You and your staff will have fewer errors and better compliance using barcoded reagents, as well as reduced hands-on time with touch-free scheduled daily maintenance, startup, and shutdown.<\/li>\n<li><strong>TECHNOLOGY FOR ALL EMPLOYEES<\/strong> &#8211; CELL DYN Emerald 22&#8217;s flexible interface is user-friendly, offering easy training of software functions using the color touch screen and numeric keypad to quickly bring employees up to speed.<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">Two pulses are generated for each cell entering the optical detection area in the interrogation zone\u00a0\u2013 Axial Light Loss and Forward Side Scatter measurement. The five-part differential is obtained by scattergram analysis after the action of the Lyse, with no dyes, stains, or special channel measurements.<\/p>\n<h3 style=\"text-align: justify;\">Enhanced Scattering Efficiency<\/h3>\n<p style=\"text-align: justify;\">The cluster separation is enhanced with the low wavelength (455 nm) blue solid-state LED. This wavelength enhances the differentiation of intracellular contents, improving the identification and separation of eosinophils and monocytes from neutrophils. The unique flow cell design, enhanced LED light source, and simple optical bench provide a true five-part differential in a small, easy-to-use, reliable analyzer.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-562 size-full\" src=\"https:\/\/dipylonmedical.com\/wp-content\/uploads\/2021\/08\/cell-dyn-emerald-22-features.jpeg\" alt=\"cell-dyn-emerald-22-features\" width=\"1280\" height=\"720\" srcset=\"https:\/\/dipylonmedical.com\/wp-content\/uploads\/2021\/08\/cell-dyn-emerald-22-features.jpeg 1280w, https:\/\/dipylonmedical.com\/wp-content\/uploads\/2021\/08\/cell-dyn-emerald-22-features-300x169.jpeg 300w, https:\/\/dipylonmedical.com\/wp-content\/uploads\/2021\/08\/cell-dyn-emerald-22-features-1000x563.jpeg 1000w, https:\/\/dipylonmedical.com\/wp-content\/uploads\/2021\/08\/cell-dyn-emerald-22-features-711x400.jpeg 711w, https:\/\/dipylonmedical.com\/wp-content\/uploads\/2021\/08\/cell-dyn-emerald-22-features-768x432.jpeg 768w, https:\/\/dipylonmedical.com\/wp-content\/uploads\/2021\/08\/cell-dyn-emerald-22-features-600x338.jpeg 600w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><\/p>\n<h4>System Specifications<\/h4>\n<div id=\"vodori_input_StampDecorator_4\" class=\"table-wrapper\" style=\"text-align: justify;\" data-dojo-type=\"vodori.input.StampDecorator\" data-dojo-props=\"\" data-qa-id=\"vodori.input.StampDecorator dijit._Widget dijit._FocusMixin dijit._OnDijitClickMixin dijit._WidgetBase\">\n<table>\n<tbody>\n<tr>\n<td>SPECIFICATIES<\/td>\n<td>DESCRIPTIONS<\/td>\n<\/tr>\n<tr>\n<td><strong>Technology &amp; Methods<\/strong><\/td>\n<td>\n<ul>\n<li>Optical Flow Cytometry technology<\/li>\n<li>Electrical impedance<\/li>\n<li>Absorption spectrophotometry<\/li>\n<li>Electronic valves<\/li>\n<li>Cyanide-free lyse reagent<\/li>\n<li>LCD color touch screen<\/li>\n<li>RS232 and TCP\/IP LIS interface<\/li>\n<li>USB ports<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td><strong>Doorvoer<\/strong><\/td>\n<td>Up to 45 samples per hour<\/td>\n<\/tr>\n<tr>\n<td><strong>Sample Size<\/strong><\/td>\n<td>17 \u03bcL<\/td>\n<\/tr>\n<tr>\n<td><strong>Specimen Data Management<\/strong><\/td>\n<td>\n<ul>\n<li>Search by date or sequence number<\/li>\n<li>Flagging for patient limit sets<\/li>\n<li>Flagging for panic values<\/li>\n<li>1,000 records with histograms on the internal memory<\/li>\n<li>Up to 300,000 records on an external USB thumb drive<\/li>\n<li>Customizable patient limits<\/li>\n<li>Customizable report units (USA, SI, SI MOD)<\/li>\n<li>A barcode reader (reads code 128, code 39, interleaved 2 of 5, and others listed in the Operator\u2019s Manual)<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td><strong>Quality Control<\/strong><\/td>\n<td>\n<ul>\n<li>6 control files<\/li>\n<li>100 runs per file<\/li>\n<li>Levey-Jennings graphs<\/li>\n<li>Upload\/download control information<\/li>\n<li>eQC online peer review program<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td><strong>Demographics<\/strong><\/td>\n<td>\n<ul>\n<li>Sequence number<\/li>\n<li>Alphanumeric specimen ID<\/li>\n<li>Date &amp; time analyzed<\/li>\n<li>Patient name<\/li>\n<li>CBC with or without 5-part differential<\/li>\n<li>Flagging and Alerts<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td><strong>Dispersion Data Alert<\/strong><\/td>\n<td>\n<ul>\n<li>Operator-defined patient limits for high and panic values<\/li>\n<li>System-defined limits for reportable range and analytical measurement range<\/li>\n<li>Suspect parameter flags caused by interfering substances or sample abnormalities<\/li>\n<li>Suspect parameter flags are generated when WBC data indicates the possible presence of an abnormal population<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td><strong>Standards &amp; Safety Compliance<\/strong><\/td>\n<td>\n<ul>\n<li>UL 61010-1<\/li>\n<li>CAN\/CSA-C22.2 No. 61010-1<\/li>\n<li>IEC 61010-1<\/li>\n<li>IEC 61326-1<\/li>\n<li>IEC 61326-2-6<\/li>\n<li>FCC part.15<\/li>\n<li>CE Mark<\/li>\n<li>ETL Mark<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td><strong>Peripheral Devices<\/strong><\/td>\n<td>\n<ul>\n<li>Inkjet or laser printer<\/li>\n<li>USB Thumb Drive<\/li>\n<li>Handheld barcode scanner<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td><strong>Physical Dimensions<\/strong><\/td>\n<td>\n<ul>\n<li>Height &#8211; 13.8 inches (35 cm)<\/li>\n<li>Width &#8211; 9.8 inches (25 cm)<\/li>\n<li>Depth &#8211; 13.8 inches (35 cm)<\/li>\n<li>Weight &#8211; approximately 24.2 lbs. (11 kg) (without onboard reagents)<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"text-align: justify;\"><strong>Parameters<\/strong><\/p>\n<div id=\"vodori_input_StampDecorator_5\" class=\"table-wrapper\" style=\"text-align: justify;\" data-dojo-type=\"vodori.input.StampDecorator\" data-dojo-props=\"\" data-qa-id=\"vodori.input.StampDecorator dijit._Widget dijit._FocusMixin dijit._OnDijitClickMixin dijit._WidgetBase\">\n<table border=\"0\">\n<tbody>\n<tr>\n<td>WHITE CELLS<\/td>\n<td>RED CELLS<\/td>\n<td>PLATELETS<\/td>\n<\/tr>\n<tr>\n<td>WBC<\/td>\n<td>RBC<\/td>\n<td>PLT<\/td>\n<\/tr>\n<tr>\n<td>NEU %<\/td>\n<td>HGB<\/td>\n<td>MPV<\/td>\n<\/tr>\n<tr>\n<td>NEU #<\/td>\n<td>HCT<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>LYM %<\/td>\n<td>MCV<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>LYM #<\/td>\n<td>MCH<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>MON %<\/td>\n<td>MCHC<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>MON #<\/td>\n<td>\u00a0RDW<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>EOS %<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>EOS #<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>BAS %<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>BAS #<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"text-align: justify;\"><strong>Reagents<\/strong><\/p>\n<div id=\"vodori_input_StampDecorator_6\" class=\"table-wrapper\" style=\"text-align: justify;\" data-dojo-type=\"vodori.input.StampDecorator\" data-dojo-props=\"\" data-qa-id=\"vodori.input.StampDecorator dijit._Widget dijit._FocusMixin dijit._OnDijitClickMixin dijit._WidgetBase\">\n<table>\n<tbody>\n<tr>\n<td>REAGENT DESCRIPTIONS<\/td>\n<td>SIZE AND LIST NUMBER<\/td>\n<\/tr>\n<tr>\n<td>CELL-DYN Emerald 22 Lyse<\/td>\n<td>500 mL (List No. 09H61-01)<\/td>\n<\/tr>\n<tr>\n<td>CELL-DYN Emerald 22 Diluent<\/td>\n<td>10 L (List No. 09H62-01)<\/td>\n<\/tr>\n<tr>\n<td>CELL-DYN Emerald 22 Easy Cleaner<\/td>\n<td>980 mL (List No. 09H60-01)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"text-align: justify;\"><strong>Controls &amp; Calibrators<\/strong><\/p>\n<div id=\"vodori_input_StampDecorator_7\" class=\"table-wrapper\" data-dojo-type=\"vodori.input.StampDecorator\" data-dojo-props=\"\" data-qa-id=\"vodori.input.StampDecorator dijit._Widget dijit._FocusMixin dijit._OnDijitClickMixin dijit._WidgetBase\">\n<table>\n<tbody>\n<tr style=\"text-align: justify;\">\n<td>SPECIFICATIES<\/td>\n<td>DESCRIPTIONS<\/td>\n<\/tr>\n<tr style=\"text-align: justify;\">\n<td>CELL-DYN 22 Plus Calibrator<\/td>\n<td>09H73-01<\/td>\n<\/tr>\n<tr style=\"text-align: justify;\">\n<td>CELL-DYN 22 Plus Control Full-Pack (12 tubes)<\/td>\n<td>09H72-01<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: justify;\">CELL-DYN 22 Plus Control Half-Pack (6 tubes)<\/td>\n<td style=\"text-align: justify;\">09H72-02<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Referentielink<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.corelaboratory.abbott\/us\/en\/offerings\/brands\/cell-dyn\/cell-dyn-emerald22\" target=\"_blank\" rel=\"noopener\">Fabrikant informatie<\/a><\/li>\n<li><a href=\"https:\/\/dipylonmedical.com\/wp-content\/uploads\/2021\/08\/cell-dyn-emerald-22-Brochure-Diplyon-Medical.pdf\" target=\"_blank\" rel=\"noopener\">Brochure<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p style=\"text-align: justify;\">CELL DYN Emerald 22 is one of the smallest 5-part differential analyzers on the market and helps laboratories like yours conserve valuable workspace.<\/p>","protected":false},"featured_media":564,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[81],"product_tag":[89],"class_list":["post-560","product","type-product","status-publish","has-post-thumbnail","product_cat-hematology-analyzer","product_tag-cell-dyn-emerald-22","first","instock","sale","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/dipylonmedical.com\/nl\/wp-json\/wp\/v2\/product\/560","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dipylonmedical.com\/nl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/dipylonmedical.com\/nl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/dipylonmedical.com\/nl\/wp-json\/wp\/v2\/comments?post=560"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dipylonmedical.com\/nl\/wp-json\/wp\/v2\/media\/564"}],"wp:attachment":[{"href":"https:\/\/dipylonmedical.com\/nl\/wp-json\/wp\/v2\/media?parent=560"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/dipylonmedical.com\/nl\/wp-json\/wp\/v2\/product_brand?post=560"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/dipylonmedical.com\/nl\/wp-json\/wp\/v2\/product_cat?post=560"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/dipylonmedical.com\/nl\/wp-json\/wp\/v2\/product_tag?post=560"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}