{"id":796,"date":"2021-09-02T09:17:54","date_gmt":"2021-09-02T09:17:54","guid":{"rendered":"https:\/\/dipylonmedical.com\/?post_type=product&#038;p=796"},"modified":"2024-03-07T16:03:41","modified_gmt":"2024-03-07T16:03:41","slug":"beckman-coulter-dxh-800","status":"publish","type":"product","link":"https:\/\/dipylonmedical.com\/ja\/product\/beckman-coulter-dxh-800\/","title":{"rendered":"Beckman Coulter DxH 800 Hematology Analyzer System"},"content":{"rendered":"<p class=\"p1\" style=\"text-align: justify;\">Beckman Coulter DxH 800 uses only five reagents for all analyses, including NRBC and reticulocytes, saving costs by reducing inventory management. Each work cell can comprise up to three DxH 800 modules and one Slidemaker Slidestainer (the UniCel DxH 2401) to form scalable and customized workflow solutions. The UniCel DxH 2401 configuration can analyze up to 300 samples and 140 slides per hour at peak performance.<\/p>\n<style>.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }<\/style>\n<div class=\"embed-container\"><iframe src=\"https:\/\/www.youtube.com\/embed\/ClLN_ISoNLs\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/div>\n<p>&nbsp;<\/p>\n<h2 class=\"p2\" style=\"text-align: justify;\"><span class=\"s1\"><b>What is the Beckman Coulter DxH 800?<\/b><\/span><\/h2>\n<p class=\"p3\" style=\"text-align: justify;\"><span class=\"s1\">The Beckman Coulter DxH 800 is an automatic hematology analyzer from the American medical company Beckman Coulter. This high volume and powerful machine is the answer to all your hematological research and experiments. With the DxH 800, you are capable of extracting information about individual cell structure and size.<\/span><\/p>\n<p class=\"p4\" style=\"text-align: justify;\"><span class=\"s1\">It is a reliable, durable, and efficient machine built for tech labs and hospitals. But there is more to this unit. Keep reading below to find out.<\/span><\/p>\n<h3 class=\"p2\" style=\"text-align: justify;\"><span class=\"s1\"><b>Overview of the DxH 800<\/b><\/span><\/h3>\n<p class=\"p3\" style=\"text-align: justify;\"><span class=\"s1\">The unit comes with its own Data Management System, which includes the monitor and printer. A floor stand (optional) is included in the package as well. This device weighs around 260 pounds and stands at the height of 96.50 cm with a 78 cm thickness of 76 cm width. It is pretty tall compared to other units of the same class.<\/span><\/p>\n<p class=\"p3\" style=\"text-align: justify;\"><span class=\"s1\">The DxH also comes with a vast storage system to save up to 40,000 patient records, including graphics. Furthermore, it can connect with three more DxH units for increased efficiency. The open\/closed vial gives us a Sample Volume capacity of 165 \u00b5l.<\/span><\/p>\n<p class=\"p3\" style=\"text-align: justify;\"><span class=\"s1\">Beckman Coulter DxH 800, with its advanced algorithm technology, can better analyze nucleated red blood cells (NRBC), white blood cells (WBC), and reticulocytes. It has yielded improved results in precisely detecting the presence of NRBCs. Furthermore, it provides clear-cut PLT and WBC counts as well.<\/span><\/p>\n<p class=\"p4\" style=\"text-align: justify;\"><span class=\"s1\">Now let us take a look closer look at the primary and technical features of this analyzing unit.<\/span><\/p>\n<h4 class=\"p2\" style=\"text-align: justify;\"><span class=\"s1\"><b>Primary and external features<\/b><\/span><\/h4>\n<ul class=\"ul1\" style=\"text-align: justify;\">\n<li class=\"li3\"><span class=\"s1\">The DxH makes sample storage easy with twenty cassettes, each with a closely packed five-tube system.<\/span><\/li>\n<li class=\"li3\"><span class=\"s1\">It comes with a hand-held barcode scanner for reading labels on specimen tubes.<\/span><\/li>\n<li class=\"li3\"><span class=\"s1\">The aspiration volume in the open\/closed vial system has a reduced volume of 165 \u00b5l. This allows the DxH 800 to take in smaller sample volumes.<\/span><\/li>\n<li class=\"li3\"><span class=\"s1\">The LCD flat panel has touch screen capabilities. And the computer runs on a Microsoft Windows XP operating system along with the DxH software.<\/span><\/li>\n<li class=\"li4\"><span class=\"s1\">An optional floor with four separate compartments can store reagents and waste in well-packed containers.\u00a0<\/span><\/li>\n<\/ul>\n<h4 class=\"p2\" style=\"text-align: justify;\"><span class=\"s1\"><b>Technical Features<\/b><\/span><\/h4>\n<ul class=\"ul1\" style=\"text-align: justify;\">\n<li class=\"li3\"><span class=\"s1\">The automatic throughput system is capable of producing 100 blood sample analyses in one hour.\u00a0\u00a0<\/span><\/li>\n<li class=\"li3\"><span class=\"s1\">It can determine up to 29 parameters, including WBC, RBC, HGB, UWBC, PLT, etc.<\/span><\/li>\n<li class=\"li3\"><span class=\"s1\">The auto-rerun and reflex testing minimize Turn Around Time (TAT).<\/span><\/li>\n<li class=\"li3\"><span class=\"s1\">A unique flow cell design can measure more light scatter, which boosts data collection and flow for multiple sample analysis.<\/span><\/li>\n<li class=\"li4\"><span class=\"s1\">The DxH 800 has another unique correction feature. This feature allows users to acquire precise RBC parameters in the presence of leukocytosis.<\/span><\/li>\n<\/ul>\n<h5 style=\"text-align: justify;\">Technical Specifications<\/h5>\n<div style=\"text-align: justify;\">\n<ul>\n<li><b>Dimensions<\/b>\n<ul>\n<li><b>Depth:\u00a0<\/b>31&#8243;<\/li>\n<li><b>Height:<\/b>\u00a038&#8243;<\/li>\n<li><b>Width:<\/b>\u00a030&#8243;<\/li>\n<\/ul>\n<\/li>\n<li><b>Weight:\u00a0<\/b>260 lbs<\/li>\n<li><b>Sample Volume:\u00a0<\/b>Open\/Closed Vial: 165 \u00b5L<\/li>\n<li><b>Parameters<\/b>\n<ul>\n<li><b>CBC Results:\u00a0<\/b>WBC, UWBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV<\/li>\n<li><b>Differential Results (absolute and %):<\/b>\u00a0NE, LY, MO, EO, BA, NRBC, NE#, LY#, MO#, EO#, BA#, NRBC#<\/li>\n<li><b>Reticulocyte Results (absolute and %):<\/b>\u00a0RET, RET#, MRV, IRF<\/li>\n<\/ul>\n<\/li>\n<li><b>Power<\/b>\n<ul>\n<li><b>Power Consumption:<\/b>\u00a01,185 W<\/li>\n<li><b>Power Requirements:<\/b>\u00a0100\u2013264 VAC and 48\u201362 HZ<\/li>\n<\/ul>\n<\/li>\n<li><b>Whole Blood Performance &#8211; Measuring Range<\/b>\n<ul>\n<li><b>WBC:\u00a0<\/b>0.000 &#8211; 400.000 X 103 \u00b5L<\/li>\n<li><b>RBC:<\/b>\u00a00.000 &#8211; 8.500 X 106 \u00b5L<\/li>\n<li><b>HGB:\u00a0<\/b>0.00 &#8211; 25.50 g\/dL<\/li>\n<li><b>MCV:<\/b>\u00a050.00 &#8211; 150.00 fL<\/li>\n<li><b>PLT:<\/b>\u00a00.0 &#8211; 3,000.0 X 103 \u00b5L<\/li>\n<li><b>NRBC:<\/b>\u00a00.00 &#8211; 600.00\/100 WBC<\/li>\n<li><b>Retic:\u00a0<\/b>0.000 &#8211; 30.000 %<\/li>\n<\/ul>\n<\/li>\n<li><b>Data Management<\/b>\n<ul>\n<li><b>Database:\u00a0<\/b>40,000 patient results with graphics<\/li>\n<li><b>Quality Assurance:\u00a0<\/b>QC with Levey-Jennings Graph, XB\/XM for Moving Averages, Daily Check, Intelligent Quality Monitoring<\/li>\n<\/ul>\n<\/li>\n<li><b>Sample Transport Capabilities<\/b>\n<ul>\n<li><b>Capacity:\u00a0<\/b>20 five-tube cassettes<\/li>\n<li><b>Bar Codes:<\/b>\u00a0Digital Bar Code with 2D Bar Code capability<\/li>\n<li><b>Sample ID:\u00a0<\/b>Up to 22 characters<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-807 size-full\" src=\"https:\/\/dipylonmedical.com\/wp-content\/uploads\/2021\/09\/Beckman-Coulter-DxH-800_banner.jpeg\" alt=\"Beckman-Coulter-DxH 800_banner\" width=\"1280\" height=\"720\" srcset=\"https:\/\/dipylonmedical.com\/wp-content\/uploads\/2021\/09\/Beckman-Coulter-DxH-800_banner.jpeg 1280w, https:\/\/dipylonmedical.com\/wp-content\/uploads\/2021\/09\/Beckman-Coulter-DxH-800_banner-300x169.jpeg 300w, https:\/\/dipylonmedical.com\/wp-content\/uploads\/2021\/09\/Beckman-Coulter-DxH-800_banner-1000x563.jpeg 1000w, https:\/\/dipylonmedical.com\/wp-content\/uploads\/2021\/09\/Beckman-Coulter-DxH-800_banner-711x400.jpeg 711w, https:\/\/dipylonmedical.com\/wp-content\/uploads\/2021\/09\/Beckman-Coulter-DxH-800_banner-768x432.jpeg 768w, https:\/\/dipylonmedical.com\/wp-content\/uploads\/2021\/09\/Beckman-Coulter-DxH-800_banner-600x338.jpeg 600w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><\/p>\n<\/div>\n<h2 class=\"p2\" style=\"text-align: justify;\"><span class=\"s1\"><b>How does the Beckman Coulter DxH 800 Operate?<\/b><\/span><\/h2>\n<p class=\"p3\" style=\"text-align: justify;\"><span class=\"s1\">The DxH uses the Coulter Method and VCS technology for accurate reading of cell structure and size.<\/span><\/p>\n<p class=\"p3\" style=\"text-align: justify;\"><span class=\"s1\">For Complete Blood Count (CBC) analysis, the following steps are followed:\u00a0<\/span><\/p>\n<ul class=\"ul1\" style=\"text-align: justify;\">\n<li class=\"li3\"><span class=\"s1\">The aspiration pump takes in 165 \u00b5l of the sample.<\/span><\/li>\n<li class=\"li3\"><span class=\"s1\">After removing the probe, the aspiration pump takes in the blood through the BSV pathway. The BSV transfers the samples and diluents to the WBC and RBC apertures baths.<\/span><\/li>\n<li class=\"li4\"><span class=\"s1\">In the WBC bath, ~6.0 ml of diluent and ~28 \u00b5l of sample mixes with ~1.08 ml of cell lyse for final dilation of 1:251. Meanwhile, in the RBC bath, ~10 ml of diluent and ~1.6 \u00b5l of the sample is mixed, giving us a final dilation of 1:6250<\/span><\/li>\n<\/ul>\n<p class=\"p5\" style=\"text-align: justify;\"><span class=\"s1\"><b>Power Requirements<\/b><\/span><\/p>\n<p class=\"p4\" style=\"text-align: justify;\"><span class=\"s1\">The DxH 800 requires a current of 100-264 V of AC and 48-62 Hz. It consumes about 1,185 Watts of power, depending on the workload.\u00a0<\/span><\/p>\n<p class=\"p6\" style=\"text-align: justify;\"><span class=\"s1\">The DxH 800 has all the features that customers would want. It is the answer to all your research and scientific needs. Overall, it is a well-built device for small labs and even large hospitals.<\/span><\/p>\n<h2 style=\"text-align: justify;\">Include<\/h2>\n<ul style=\"text-align: justify;\">\n<li>keyboard<\/li>\n<li>Pneumatic Vacuum Supply<\/li>\n<li>Beckman Coulter DxH Cellular Analysis Systems Cell Lyse, 1 x 5 L 628019<\/li>\n<li>ASSY REMANUFACTURED ASSY SCA DXH 800<\/li>\n<li>Beckman Coulter DxH Cleaner (10L)<\/li>\n<li>Beckman Coulter Body Fluid Control (4 x 3.5 mL) (Box of 12)<\/li>\n<li>Beckman Coulter 6C Cell Control (4 x 3.5 mL) (Box of 12)<\/li>\n<li>Range of tests<\/li>\n<li>Time per analysis<\/li>\n<li>Automation<\/li>\n<li>Reagent supply<\/li>\n<li>Sample size and microsampling<\/li>\n<li>Accuracy, precision, and linearity<\/li>\n<li>Maintenance, calibration, and QC<\/li>\n<li>Results analysis and storage<\/li>\n<li>Footprint.<\/li>\n<li>1-Year Warranty<\/li>\n<\/ul>\n<h2 style=\"text-align: justify;\">Reference Link<\/h2>\n<ul>\n<li style=\"text-align: justify;\"><a href=\"https:\/\/www.beckmancoulter.com\/products\/hematology\/dxh-800\" target=\"_blank\" rel=\"noopener\">Manufacturer Information<\/a><\/li>\n<li style=\"text-align: justify;\"><a href=\"https:\/\/dipylonmedical.com\/wp-content\/uploads\/2021\/09\/Beckman-Coulter-DxH-800_Brochure.pdf\">Brochure<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p class=\"p3\" style=\"text-align: justify;\"><span class=\"s1\">Beckman Coulter DxH 800 is an automatic hematology analyzer with a high volume and powerful machine for research and experiments.\u00a0<\/span><\/p>","protected":false},"featured_media":798,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[81],"product_tag":[142],"class_list":["post-796","product","type-product","status-publish","has-post-thumbnail","product_cat-hematology-analyzer","product_tag-beckman-coulter-dxh-800","first","instock","sale","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/dipylonmedical.com\/ja\/wp-json\/wp\/v2\/product\/796","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dipylonmedical.com\/ja\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/dipylonmedical.com\/ja\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/dipylonmedical.com\/ja\/wp-json\/wp\/v2\/comments?post=796"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dipylonmedical.com\/ja\/wp-json\/wp\/v2\/media\/798"}],"wp:attachment":[{"href":"https:\/\/dipylonmedical.com\/ja\/wp-json\/wp\/v2\/media?parent=796"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/dipylonmedical.com\/ja\/wp-json\/wp\/v2\/product_brand?post=796"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/dipylonmedical.com\/ja\/wp-json\/wp\/v2\/product_cat?post=796"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/dipylonmedical.com\/ja\/wp-json\/wp\/v2\/product_tag?post=796"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}