{"id":1075,"date":"2022-09-15T17:42:08","date_gmt":"2022-09-15T17:42:08","guid":{"rendered":"https:\/\/dipylonmedical.com\/?post_type=product&#038;p=1075"},"modified":"2025-09-15T12:34:27","modified_gmt":"2025-09-15T12:34:27","slug":"cobas-e-411","status":"publish","type":"product","link":"https:\/\/dipylonmedical.com\/es\/product\/cobas-e-411\/","title":{"rendered":"Roche Cobas e411 Chemistry Analyzer"},"content":{"rendered":"<p style=\"text-align: justify;\"><strong>Cobas e 411<\/strong> analyzer is fully automated and uses patented electrochemiluminescence (ECL) technology to perform immunoassay analyses. It has been developed for various applications for quantitative and qualitative in vitro assays (including anemia markers and bone, cardiac and tumor markers, critical care, fertility\/hormones, pregnancy care, and infectious diseases). The analyzer is available as a rack system or disk system.<\/p>\n<p style=\"text-align: justify;\">The Cobas e 411 combines the reliability of Roche\/Hitachi systems with the analytical excellence of electrochemiluminescence, creating an excellent immunoassay system. By providing 18 simultaneous immunology parameters 24\/24 hours, the Cobas e 411 offers high availability and response times of 9 to 27 minutes. Multifaceted, it both automates immunoassays in small and medium-sized laboratories and serves to perform specialties in more extensive laboratories.<\/p>\n<p style=\"text-align: justify;\">The extensive test menu sets the Cobas e 411 apart. Roche&#8217;s Clinical Chemistry and Immunology test menu, the most comprehensive on the market, allows you to run routine and special parameters on the same analytical platform. The laboratory can thus provide differentiated and regular tests simultaneously and in good time, with maximum analytical quality.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\"><iframe loading=\"lazy\" title=\"Cobas E411 Operation and Daily Mainteinance Special Chemistry Analyser\" src=\"https:\/\/www.youtube.com\/embed\/XiuQJGhpk_o\" width=\"868\" height=\"488\" frameborder=\"0\"><\/iframe><\/p>\n<h2 style=\"text-align: justify;\">Performing immunoassays as efficiently as clinical chemistry<\/h2>\n<p style=\"text-align: justify;\">The Cobas e 411 system is a fully automatic Autoanalyzer applied to the immune analysis, whose measurement basis is Electrochemiluminescence (ECL). ECL technology uses streptavidin-coated magnetic microparticles as a solid phase, antigen\/antibody interactions, and interference suppression methods.<\/p>\n<p style=\"text-align: justify;\">The measurement cell where the electrochemiluminescent reaction takes place allows obtaining results in 9 minutes (STAT Test) or 18 minutes at a speed of approximately 90 determinations per hour.<\/p>\n<p style=\"text-align: justify;\">It is a patient-oriented, continuous access instrument that provides the laboratory with improvements that translate into extreme simplicity and ease of use, with reliable results and a robust instrument.<\/p>\n<h2 style=\"text-align: justify;\">Roche Cobas e411 Chemistry Analyzer Features:<\/h2>\n<ul style=\"list-style-type: disc; text-align: justify;\">\n<li>High sensitivity, reliability, and reproducibility of results due to ECL technology<\/li>\n<li>Up to 18 assays can be run at a throughput of up to 86 tests\/h<\/li>\n<li>9 min STAT applications for emergency sample essays (incl. TnT Gen. 5, Creatine-Kinase MB, Myoglobin, Parathyroid Hormone (PTH), and human Chorionic Gonadotropin (hCG)1<\/li>\n<li>Carryover-free pipetting of samples to avoid cross-contamination<\/li>\n<li>Automated sample rerun capability<\/li>\n<li>Continuous random access and flexible STAT priority settings<\/li>\n<li>The use of disposable tips for all selection pipetting delivers carryover free pipetting to prevent cross-contamination<\/li>\n<li>Economic usage with high stabilities and convenient kit sizes<\/li>\n<li>Increased uptime of 98.6%<\/li>\n<li>Low system maintenance time<\/li>\n<li>Fully automatic immunological analyzer with up to 88 t \/ h.<\/li>\n<li>It needs the shortest time to obtain the final result of all immunological analyzers \u2013 between 9 and 18 minutes. This is because the measurement method is ECL, which also allows a broader measurement range and greater sensitivity and needs smaller quantities of serum.<\/li>\n<li>Possibility of continuous addition of samples at any moment of the process.<\/li>\n<li>Possibility of setting urgent samples under STAT.<\/li>\n<li>The unique concept of programming is just by inserting the reagents, calibrators, controls, and serums into the instrument and its launch. At the start, the device detects the barcode and starts working. This option increases efficiency in the laboratory.<\/li>\n<li>A wide range of tests of over 75 covers the seven different areas of indication. It is desirable to note that, unlike some instruments, there is no need for any selectivity through indication areas by defining the tests.<\/li>\n<li>The reagents do not need any preparation (Ready To Use); they are on the drive with temperature control.<\/li>\n<li>During the work at each pipetting, the reagents open and close automatically, protecting them from external influences at every moment of the process.<\/li>\n<li>This possibility to automatically open and close the reagents and temperature control increases the durability of the reagents inserted on the instrument to 60 days, even for the most sensitive tests.<\/li>\n<li>Excellent stability of calibration of the lot has changed significantly reduced costs.<\/li>\n<li>The reliability of the results in every moment of the process, despite the increased stability of reagents and calibrations, also contributes to the detection level and opening coagulum (Clot Detection).<\/li>\n<li>The possibility of transmission and contamination of the sample is reduced by using special pipettors for one use only at any pipetting of serum or reagent. This is another fact that increases the reliability of the results.<\/li>\n<li>Ability to work with serum, plasma, and urine.<\/li>\n<li>System software is perfected and standardized with all Cobas platforms. Performance of the PC \u2013 is significantly improved compared to the Elecsys 2010. Here are the most significant changes made in respect of Elecsys 2010 to simplify the system for the user.<\/li>\n<\/ul>\n<h3 style=\"text-align: justify;\">Benefits<\/h3>\n<ul style=\"list-style-type: disc; text-align: justify;\">\n<li>Easy to Operate<\/li>\n<li>Innovative technology<\/li>\n<li>STAT facilities for urgent sample<\/li>\n<li>Unique programming-by-loading concept<\/li>\n<\/ul>\n<h3 style=\"text-align: justify;\">Assay menu<\/h3>\n<ul style=\"list-style-type: disc; text-align: justify;\">\n<li>Thyroid Function<\/li>\n<li>Fertility \/ Hormones<\/li>\n<li>Anemia<\/li>\n<li>Tumor Markers<\/li>\n<li>Cardiac<\/li>\n<li>Maternal Care<\/li>\n<li>Critical Care<\/li>\n<li>Infectious Disease<\/li>\n<li>Bone Markers<\/li>\n<\/ul>\n<h2 style=\"text-align: justify;\">Three ways to achieve unmatched performance<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1078 size-full\" src=\"https:\/\/dipylonmedical.com\/wp-content\/uploads\/2022\/09\/cobas-e411-dipylon-medical.jpeg\" alt=\"Cobas e 411\" width=\"881\" height=\"607\" srcset=\"https:\/\/dipylonmedical.com\/wp-content\/uploads\/2022\/09\/cobas-e411-dipylon-medical.jpeg 881w, https:\/\/dipylonmedical.com\/wp-content\/uploads\/2022\/09\/cobas-e411-dipylon-medical-300x207.jpeg 300w, https:\/\/dipylonmedical.com\/wp-content\/uploads\/2022\/09\/cobas-e411-dipylon-medical-581x400.jpeg 581w, https:\/\/dipylonmedical.com\/wp-content\/uploads\/2022\/09\/cobas-e411-dipylon-medical-768x529.jpeg 768w, https:\/\/dipylonmedical.com\/wp-content\/uploads\/2022\/09\/cobas-e411-dipylon-medical-50x34.jpeg 50w, https:\/\/dipylonmedical.com\/wp-content\/uploads\/2022\/09\/cobas-e411-dipylon-medical-600x413.jpeg 600w\" sizes=\"auto, (max-width: 881px) 100vw, 881px\" \/><\/p>\n<p style=\"text-align: justify;\">As the heart of the Cobas e 411 analyzers, ECL technology delivers the unique combination of nine-minute STAT applications, high analytical sensitivity, and wide measuring ranges for unparalleled performance in immunochemistry.<\/p>\n<ul style=\"list-style-type: disc; text-align: justify;\">\n<li>Wide measuring ranges reduce the amount of tests rerun due to out-of-range results<\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><strong>Examples:<\/strong><\/p>\n<p style=\"text-align: justify;\">-Estradiol range of 5 \u2013 4,300 pg\/mL<\/p>\n<p style=\"text-align: justify;\">-Progesterone range of 0 \u2013 60 ng\/mL<\/p>\n<p style=\"text-align: justify;\">-total-PSA range of 0 \u2013 100 ng\/mL<\/p>\n<ul style=\"list-style-type: disc; text-align: justify;\">\n<li>High analytical sensitivity enables the use of innovative tests and requires less sample volume examples:<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">-Troponin T 4th gen. with &lt;10% cv at 95th population percentile<\/p>\n<p style=\"text-align: justify;\">-hCG+\u201a and TSH requires 10 and 50 \u03bcL sample volume, respectively<\/p>\n<ul style=\"list-style-type: disc; text-align: justify;\">\n<li>Nine minutes STAT applications deliver unmatched turnaround time for emergency samples<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">-hCG+\u00df, Troponin T 4th Gen., CK-MB, Myoglobin, PTH*<\/p>\n<h2 style=\"text-align: justify;\">Roche Cobas e411 Specifications<\/h2>\n<table style=\"border-collapse: collapse; border-spacing: 0px; border: 1px solid #eeeeee; margin: 0px 0px 15px; width: 1014px; color: #666666; font-family: 'geom-graphic', sans-serif; font-size: 16px; background-color: #ffffff;\" border=\"0\" width=\"100%\" cellpadding=\"0\">\n<tbody>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">System<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Fully automated immunoassay analyzer for random access processing of ECL-based immunoassays (<b style=\"margin: 0px; padding: 0px; border: 0px; vertical-align: baseline; background: transparent;\">Cobas e<\/b>\u00a0system format)<\/span><\/div>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Types of modules<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<ol style=\"margin: 0px; padding: 0px 0px 23px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; list-style-position: inside; line-height: 26px;\" type=\"1\">\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><b style=\"margin: 0px; padding: 0px; border: 0px; vertical-align: baseline; background: transparent;\">cobas e<\/b><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">\u00a0411 disk analyzer<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><b style=\"margin: 0px; padding: 0px; border: 0px; vertical-align: baseline; background: transparent;\">cobas e<\/b><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">\u00a0411 rack analyzer<\/span><\/li>\n<\/ol>\n<div style=\"margin: 0in 0in 0pt .5in; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><\/div>\n<ol style=\"margin: 0px; padding: 0px 0px 23px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; list-style-position: inside; line-height: 26px;\" start=\"3\" type=\"1\">\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Optional System Table (cabinet); Optional System Table Extension (for printer)<\/span><\/li>\n<\/ol>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">System components<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Self-contained bench top analyzer comprising an analytical unit and a customized user interface<\/span><\/div>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">System interfaces<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">RS232 serial interface, bidirectional<\/span><\/div>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Throughput<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Up to 86 tests\/hour<\/span><\/div>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Number of reagent channels<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">18 channels (reagent slots) for a maximum of 18 tests<\/span><\/div>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Programmable test parameters<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">N\/A, programming-by-loading (PBT) concept, application data are transferred without operator intervention from the 2D barcode of the reagent pack (RP) into the instrument database<\/span><\/div>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Sample material<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Serum\/plasma, urine, others<\/span><\/div>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Sample input\/output<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<ol style=\"margin: 0px; padding: 0px 0px 23px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; list-style-position: inside; line-height: 26px;\" type=\"1\">\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Disk Model: 30 positions for samples, calibrators, and controls<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Rack Model: 15 racks with five samples each (= 75 samples in\/out)<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">STAT port: STAT samples are processed with priority<\/span><\/li>\n<\/ol>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Sample volume<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">10 \u2013 50 \u03bcl<\/span><\/div>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Sample clot detection<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Standard (pressure sensor)<\/span><\/div>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Sample barcode types<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Code 128; Codabar (NW 7); Interleaved 2 of 5; Code 39<\/span><\/div>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Control unit<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Microsoft<span style=\"margin: 0px; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; height: 0px; line-height: 1;\">\u00ae<\/span>\u00a0Windows<span style=\"margin: 0px; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; height: 0px; line-height: 1;\">\u00ae<\/span>\u00a0XP-based panel PC<\/span><\/div>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Calibrator\/QC input<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><b style=\"margin: 0px; padding: 0px; border: 0px; vertical-align: baseline; background: transparent;\">cobas e<\/b><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">\u00a0system-specific barcoded CalSet vials on disk or racks<\/span><\/div>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Calibration methods<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Lot calibration (L-cal); Reagent Pack (RP) calibration (R-Cal)<\/span><\/div>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">QC methods<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<ol style=\"margin: 0px; padding: 0px 0px 23px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; list-style-position: inside; line-height: 26px;\" type=\"1\">\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Individual QC and cumulative QC<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Up to 100 controls pre-programmable<\/span><\/li>\n<\/ol>\n<div style=\"margin: 0in 0in 0pt .5in; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><\/div>\n<ol style=\"margin: 0px; padding: 0px 0px 23px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; list-style-position: inside; line-height: 26px;\" start=\"3\" type=\"1\">\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Preventive QC after calibration of the stand-by\u00a0<b style=\"margin: 0px; padding: 0px; border: 0px; vertical-align: baseline; background: transparent;\">Cobas e<\/b>\u00a0packs<\/span><\/li>\n<\/ol>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Data storage capacity<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<ol style=\"margin: 0px; padding: 0px 0px 23px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; list-style-position: inside; line-height: 26px;\" type=\"1\">\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">The memory contains data files necessary for the analyzer and software to work together:<\/span>\n<ul style=\"margin: 0px; padding: 2px 0px 2px 35px; border: 0px; vertical-align: baseline; background: transparent; list-style: disc; line-height: 26px;\" type=\"circle\">\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">\u2013\u00a0Reagent Data File: Up to 300 reagent packs<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">\u2013\u00a0Sample Data File: Up to 2000 test records (for samples and controls)<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">\u2013\u00a0Calibration Data File: Up to 160 calibrators<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">\u2013\u00a0QC Data File: Capacity up to 100 controls<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">\u2013\u00a0Operating Parameter Data File: Up to 305 reagent applications<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">\u2013\u00a0Up to 20 operator IDs<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Electrical requirements<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<ol style=\"margin: 0px; padding: 0px 0px 23px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; list-style-position: inside; line-height: 26px;\" type=\"1\">\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">230\/110 Volts AC; 1,000 kVA (disk), 1,250 kVA (rack)<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Frequency: 50 Hz or 60 Hz +\/- 0.5%<\/span><\/li>\n<\/ol>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Water\/Waste requirements<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<ol style=\"margin: 0px; padding: 0px 0px 23px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; list-style-position: inside; line-height: 26px;\" type=\"1\">\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Water: Bacteria-free, de-ionized water supply, the resistance of &lt; 10 \u03bcS\/cm<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Liquid waste: Onboard waste container (4 liters), direct drain optional<\/span><\/li>\n<\/ol>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Operating conditions<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<ol style=\"margin: 0px; padding: 0px 0px 23px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; list-style-position: inside; line-height: 26px;\" type=\"1\">\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Ambient temperature: 18 to 32\u00b0C<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Ambient humidity: 20 to 80% RH (without condensation)<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Heat Output: 2,879 kJ\/hr (analyzer unit)<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Noise Output: 60 dBA (stand-by), 63 dBA (operation avg.)<\/span><\/li>\n<\/ol>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Physical dimensions<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<ol style=\"margin: 0px; padding: 0px 0px 23px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; list-style-position: inside; line-height: 26px;\" type=\"1\">\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Width (disk\/rack): 120 cm \/ 170 cm 47.2 in \/ 67 in<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Depth (disk\/rack): 73 cm \/ 95 cm 28.7 in \/ 37.4 in<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Height: 80 cm \/ 31.4 in (closed top cover) 109 cm \/ 43 in (opened top cover)<\/span><\/li>\n<\/ol>\n<\/td>\n<\/tr>\n<tr style=\"padding: .857em .587em; max-width: 100%;\">\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<div style=\"margin: 0px; padding: 0px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Weight<\/span><\/div>\n<\/td>\n<td style=\"border: #f0f0f0; padding: .75pt; max-width: 100%; background-color: transparent;\" valign=\"top\">\n<ol style=\"margin: 0px; padding: 0px 0px 23px; border: 0px; font-size: 16px; vertical-align: baseline; background: transparent; list-style-position: inside; line-height: 26px;\" type=\"1\">\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Disk: 180 kg \/ 397 lbs<\/span><\/li>\n<li style=\"margin: 0in 0in 10pt; padding: 0px; border: 0px; vertical-align: baseline; background: transparent; line-height: normal;\"><span style=\"margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background: transparent;\">Rack: 250 kg \/ 551 lbs<\/span><\/li>\n<\/ol>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 style=\"text-align: justify;\">Incluir:<\/h2>\n<ul style=\"list-style-type: disc; text-align: justify;\">\n<li>ANTIMULLERIAN HORMONE (AMH) Reagent for Roche Elecsys 2010 \/ Cobas E411<\/li>\n<li>TROPONIN THS Elecsys Reagent for Roche Elecsys 2010 \/ Cobas E411<\/li>\n<li>PRECICONTROL AMH for Roche Elecsys 2010 \/ Cobas E411<\/li>\n<li>PAPP-A Elecsys Reagent for Roche Elecsys 2010 \/ Cobas E411<\/li>\n<li>CALCITONIN Reagent for Roche Elecsys 2010 \/ Cobas E411<\/li>\n<li>N-MID OSTEOCALSIN Elecsys Reagent for Roche Elecsys 2010 \/ Cobas E411<\/li>\n<li>VITAMIN D TOTAL II Reagent for Roche Elecsys 2010 \/ Cobas E411 \u2013 100 Test<\/li>\n<li>CALSET CALSITONIN for Roche Elecsys 2010 \/ Cobas E411<\/li>\n<li>FREE HCG beta Elecsys Reagent for Roche Elecsys 2010 \/ Cobas E411<\/li>\n<li>ANTI-HCV II Elecsys Reagent for Roche Elecsys 2010 \/ Cobas E411<\/li>\n<li>ANTI-HAV GEN.2 Elecsys Reagent for Roche Elecsys 2010 \/ Cobas E411<\/li>\n<li>ROCHE COBAS E411 IMMUNOLOGY SAMPLE RACK SET<\/li>\n<\/ul>\n<h2 style=\"text-align: justify;\">Reference Library<\/h2>\n<ul style=\"list-style-type: disc; text-align: justify;\">\n<li><a href=\"https:\/\/diagnostics.roche.com\/global\/en\/products\/instruments\/cobas-e-411-ins-502.html\" target=\"_blank\" rel=\"nofollow noreferrer noopener\">Informaci\u00f3n del fabricante<\/a><\/li>\n<li><a href=\"https:\/\/www.bioagilytix.com\/wp-content\/uploads\/2020\/09\/roche-cobas-e411-tests-menu.pdf\" target=\"_blank\" rel=\"nofollow noreferrer noopener\">Cobas e411 test menu<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p style=\"text-align: justify;\"><strong>Cobas e 411<\/strong> creates an excellent immunoassay system and offers high availability and response times of 9 to 27 minutes.<\/p>","protected":false},"featured_media":1077,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[187],"product_tag":[190],"class_list":["post-1075","product","type-product","status-publish","has-post-thumbnail","product_cat-chemistry-analyzer","product_tag-cobas-e-411","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/dipylonmedical.com\/es\/wp-json\/wp\/v2\/product\/1075","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dipylonmedical.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/dipylonmedical.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/dipylonmedical.com\/es\/wp-json\/wp\/v2\/comments?post=1075"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dipylonmedical.com\/es\/wp-json\/wp\/v2\/media\/1077"}],"wp:attachment":[{"href":"https:\/\/dipylonmedical.com\/es\/wp-json\/wp\/v2\/media?parent=1075"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/dipylonmedical.com\/es\/wp-json\/wp\/v2\/product_brand?post=1075"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/dipylonmedical.com\/es\/wp-json\/wp\/v2\/product_cat?post=1075"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/dipylonmedical.com\/es\/wp-json\/wp\/v2\/product_tag?post=1075"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}